Base Q

analog gas meter
for sizes G1,6; G2,5; G4; G6
Advantages
measurement accuracy
we guarantee a class of accuracy 1.5
in the stated range of flow rates
durability
all nodes are designed for reliable
operation over 20 years
modem connector
the possibility of integration with
remote systems
thermal stability
stable operation in the specified
temperature range
thoughtful design
that does not require
maintenance
temperature correction
the measured volume is displayed adjusted to standard conditions
Technical Specifications
Parameter name / Meter size G1,6 G2,5 G4 G6 G10
Nominal consumption, Qnom, m³/h 1,6 2,5 4 6 10
Maximum flow rate, Qmax, m³/h 2,5 4 6 10 16
Minimum consumption, Qmin, m³/h
  • standard execution
0,016 0,025 0,04 0,06 0,1
  • custom execution
0,016 0,016 0,025
Transitional consumption, Qt, m³/h 0,25 0,4 0,6 1 1,6
Nominal cyclic volume, dm³ 1,2 2 3,5
Nominal connection diameter, mm/thread of connecting fittings (ISO 228-1) (depending on the order) 20/G3/4; 25/G1; 32/G1 1/4 32/G1 1/4 32/G1 1/4;
40/G1 3/4;
50/G2
Mass, kg, max 1,9 3,3 4,2
The distance between connecting fittings, mm 110/130 250 250
Overall dimensions LxWxH, mm, max 205х168х220 338х174х248 351х210
х311
The average pressure drop value for flow Qmax, Pa, max:
  • When released from production and after repairs
200 300
  • During operation
220 330
Capacity of the measuring device, m³ 99999,999 99999,99
The price of the smallest division of the measuring device, dm³ 0,2 2
Class accuracy 1,5
Class of external mechanical conditions М1
The limits of allowable relative error in the range intervals of volumetric flow rate at a temperature of (20±2) °C:
  • Upon release from production and after repair:
 in the flow range from Qt ≤ Q ≤ Qmax ± 1,5 %
 in the flow range from Qmin ≤ Q < Qt ± 3 %
  • During operation:
 in the flow range from Qt ≤ Q ≤ Qmax ± 3 %
 in the flow range from Qmin ≤ Q < Qt from minus 6% to 3%
Sensitivity threshold, max, m³/h 0,003
Maximum excess working pressure 50 kPa (0,5 bar)
Operating temperature range, °C from minus 25 to 55
Standard gas temperature, tb, °C * 20
The specified average temp., tsp, °C * 20
Service life 20 years

* – for the model with a built-in temperature conversion device