Next Q

smart gas meter with NB-IoT technology
for sizes G1,6; G2,5; G4; G6
Advantages
modern design
clean lines, functionality
and harmony
device geolocation
determination of location when establishing and transmitting information
protected compartment
IP protection grade 65 for all
electronic components
built-in modem
integration with
remote systems
measurement accuracy
we guarantee a class of accuracy 1.5
in the stated range of flow rates
remote setup
remote firmware update
and settings
fixation of interference attempts
registration of unauthorized actions and notification of the operator
long autonomous operation
8 years of full operation
from 1 battery
temperature correction
the measured volume is displayed adjusted to standard conditions
Technical specifications
Parameter name / Meter size G1,6 G2,5 G4 G6
Nominal consumption, Qnom, m³/h 1,6 2,5 4 6
Maximum flow rate, Qmax, m³/h 2,5 4 6 10
Minimum consumption, Qmin, m³/h
  • standard execution
0,016 0,025 0,04 0,06
  • custom execution
0,016 0,016 0,025
Transitional consumption, Qt, m³/h 0,25 0,4 0,6 1
Nominal cyclic volume, dm³ 1,2 2
Nominal connection diameter, mm/thread of connecting fittings (ISO 228-1) (depending on the order) 20/G3/4; 25/G1; 32/G1 1/4 32/G1 1/4
Mass, kg, max 2,2 4,1
The center-to-center distance between connecting fittings, mm 110/130 250
Dimensions HxWxD, mm, max 205х168х220 338х174х248
Class accuracy 1,5
Class of external mechanical conditions М1
The limits of allowable relative error in the range intervals of volumetric flow rate at a temperature of (20±2) °C:
  • Upon release from production and after repair:
 in the flow range from Qt ≤ Q ≤ Qmax ± 1,5 %
 in the flow range from Qmin ≤ Q < Qt ± 3 %
  • During operation:
 in the flow range from Qt ≤ Q ≤ Qmax ± 3 %
 in the flow range from Qmin ≤ Q < Qt from minus 6% to 3%
Sensitivity threshold, max, m³/h 0,003
Maximum excess working pressure 50 kPa (0,5 bar)
The average pressure drop value for flow Qmax, Pa, max:
  • When released from production and after repairs
200
  • During operation
220
Capacity of the measuring device, m³ 99999,999
Operating temperature range, °C from minus 25 to 55
Relative humidity of air at a temperature not exceeding 25 °C without
condensation of moisture. %
up to 95
Standard gas temperature, tb, °C * 20
The specified average temp., tsp, °C * 20
Carrier frequency, MHz Band 3 (1800 MHz)
Band 8 (900 MHz)
Maximum radiated power of LTE-MTC/eMTC and
NB-IoT, max, dBm.
23,0
Voltage supply, V до 3,6
The price of the smallest division of the measuring device, dm³ 0,2
Service life 20 years

* – for the model with a built-in temperature conversion device